Skip to content
Unique Engineers.

Industries we serve

Data Centre.

MEPF, civil works and building intelligence for data centres. Every system between the utility intake and the rack, from one contractor.

14
Data centre projects
Nine operators and EPC partners, from government server rooms to rated 4 hyperscale colocation
8
Under execution
CtrlS in Navi Mumbai and Hyderabad, Digital Edge, AdaniConneX and Anant Raj
₹344+ cr
Work orders on active projects
Eight active projects across five featured locations
3
Repeat clients
CtrlS with five active projects across two locations, Anant Raj with two orders on one campus, and Larsen and Toubro on STT Mumbai and AdaniConneX Hyderabad

What we deliver in a data centre

Every system between the utility intake and the rack.

Engineered, installed and commissioned by one contractor.

Scroll to move through the building

  1. Cooling plant and hydronics, shown in a model of the facility

    01HVAC

    Cooling plant and hydronics

    Chillers and cooling towers, primary and secondary pumping, N+1 and 2N distribution, thermal energy storage, PICV balancing, sectional isolation and cross ties for concurrent maintainability.

    13.5 kmChilled water piping at Digital Edge BOM131With 26 client supplied thermal storage tanks and 26 split case pumps
  2. Precision cooling and white space, shown in a model of the facility

    02HVAC

    Precision cooling and white space

    CRAH and PAC units, in row cooling, aisle containment, rear door heat exchangers, liquid cooling ready paths with CDU integration, zoned leak detection.

    60Fan wall units at AdaniConneX HYD 23With 22 free issue chillers and 72 precision AHUs
  3. Critical power, shown in a model of the facility

    03Electrical

    Critical power

    33, 22 and 11 kV HT systems, transformers, LT switchgear, bus ducts, 2N A and B paths, UPS and battery rooms with hydrogen sensing, DG synchronisation, HSD fuel systems.

    5 tiersOf wire mesh containment at CtrlS HYD 141LT feeders to 16 line ups, with rack whips and sockets
  4. Plumbing and drainage, shown in a model of the facility

    04Plumbing

    Plumbing and drainage

    Water supply and make up water for the cooling plant, floor drainage for data halls and technical rooms, sanitary installations, water treatment and rainwater harvesting.

    CtrlS HYD 141, HyderabadFloor drainage for halls, panel and battery rooms. Toilet water supply and drainage, with traps, supports and insulation.
  5. Fire and life safety, shown in a model of the facility

    05Fire

    Fire and life safety

    Very early smoke detection, double interlock pre action sprinklers, clean agent suppression, hydrants, high pressure water mist, foam, fire rated compartmentation.

    AdaniConneX HYD 22 and 23Double interlock pre action sprinklers with nitrogen generation, internal and external hydrants with monitors, high pressure water mist on stainless steel tube, and electric, diesel, jockey and booster fire pumps.
  6. BMS, EPMS, DCIM and security, shown in a model of the facility

    06BMS and ELV

    BMS, EPMS, DCIM and security

    PLC plant control, BMS supervision, electrical power monitoring and DCIM interfaces on open protocols. Access control, CCTV, water and liquid leak detection, public address, structured cabling and fire alarm integration.

    CtrlS DC6 and 7DDC controls and MaxCool PLC integration. VESDA, water leak detection, fire alarm, access control, PA and CCTV. EPMS communications and ELV networks.
  7. Civil interiors, shown in a model of the facility

    07Civil

    Civil interiors

    Raised floors, partitions and false ceilings in data halls, equipment plinths and foundations, trenches, fire stopped penetrations.

    4 floorsFitted out inside a live data centreCtrlS DC6 and 7, floors 6 to 9
  8. Testing and commissioning, shown in a model of the facility

    08All services

    Testing and commissioning

    Factory and site acceptance, L1 to L5 commissioning, load bank testing, integrated systems testing of failure scenarios, operator witnessed records.

    275Rack load banks of 19 kW at CtrlS DC6 and 7A 90 day commissioning team, witnessing L2 and L3 and leading L4 and L5

Why Unique Engineers

Value we add beyond installing the specification.

Eight things clients get from us in addition to the installation itself. The first five each have a page of their own.

Start a conversation

Let’s discuss your project.

Get in touch